modularheads02

  

 

 

 

AAV3 - Air Velocity & Temperature

Measures air velocity. Use to estimate CFM and also display temperature. Use with DL2 Data Logger to find average airflow and print all data out from a pc.

  • Max Operating Temp: 48.8°C
  • Realtime and Average function

Air Velocity

  • Ft/min, meters/sec, MPH, KM/hr
  • Range: 0.406 to 29.9m/sec
  • Accuracy: +/- 3% + 1dgt

Temperature

  • Display °F or °C
  • Range: -20°C to 60°C
  • Accuracy +/-0.6°C from 0°C to 45°C
  • Resolution: 0.5°C

View Operation Manual in PDF here.

AAV3
ACM3
ACMP3

ACM3 - Carbon Monoxide

Measures CO in the air and finds CO sources.

  • Fast enough to find CO source in ‘walk around’ mode
  • Response time: <70 sec to 90% of reading. 3 Pin sensor for better performance
  • Optional pump (ACMP3)
  • Auto off can be disabled for data logging
  • Select realtime or average
  • Range: 0 - 1000PPM (2000PPM with 5 minute max exposure)
  • Accuracy: 0-35ppm +/-5% reading +/-2ppm after zeroing
  • Sensor type: Electromechanical (specific to CO)

View Operation Manual in PDF here.

ACH4 - Current Clamp

Measures up to 400AAC. New clamp design for easy one handed operation.

  • Current Range: 1A to 400A
  • Accuracy: +/- 1.5% rdg +/- 0.5amp
  • Maximum conductor size: 23mm

View Operation Manual in PDF here.

ACH4

AUA2 - Milli-Micro Amp

Measure microamps for flame diode test. Measure 4 - 20mA control circuits.

  • Includes flame diode adapter
  • Max Current: 200mA AC/DC

View Operation Manual in PDF here.

AUA2
AUA2-cables

AMD1 - Microwave Oven Diode Testing

Tests high voltage diodes commonly found to fail in microwave ovens.

  • Contains 9V battery to test high voltage diodes
  • Identifies opens, shorts and correct forward voltage drop

View Operation Manual in PDF here.

AMD1_v02

ARH4 - Digital Psychrometer

Measures air temperature, RH% and dew point. Wet bulb for getting target superheat from charts.

  • Select °C or °F
  • Accuracy: +/- 1° @ 0° - 45°C +/- 2.5% RH, 10% - 90% RH @ 25°C
  • Auto off can be disabled for data logging with DL2

View Operation Manual in PDF here.

ARH4

AOX2 - Oxygen Accessory

Measure oxygen in the air for combustion analysis. Also measure %CO and stack temperature.

  • Display CO, O and or temp
  • Field calibratable K-type thermometer
  • Stable light LED indicates when the reading is stable
  • %O range: 0 - 30%, Accuracy: +/-0.3%FS
  • Temp range: -50°C - 400°C, Accuracy +/-1°
Fieldpiece_AOX2

ASH3 - Superheat Accessory

Measure suction line pressure and temperature to calculate superheat.

  • Select R-22 or R-410A
  • Includes ATC1 pipe clamp thermocouple

View Operation Manual in PDF here.

ASH3
ATC1-new03

ASX14 - Superheat/Subcool Accessory

Measures suction line or liquid line pressure and temperature to calculate superheat or subcooling for A/C.

  • Select R-22 or R-410A
  • Includes ATC1 pipe clamp thermocouple

View Operation Manual in PDF here.

ASX14
ATC1-new02

ASX24 - Superheat/Subcool Accessory

Measures suction line or liquid line and temperature to calculate superheat or subcooling for refrigeration.

  • Select R-134A or R-404A
  • Includes ATC1 pipe clamp thermocouple

View Operation Manual in PDF here.

ASX24
ATC1-new

ADMN2 - Dual Port Manometer Accessory

Accessory head that measures differential, absolute and static pressures.

  • Range from 0.00 to +/-60.0 inWC
  • Accuracy of +/-1.5% FS
  • Resolution to 0.01 inWC for static pressure measurements
  • Includes tubes and adaptors

View Operation Manual in PDF here.

ADMN2

AMN2 - Manometer Accessory

Measures gas pressure and resolution low enough for static pressures.

  • Max 20” WC for gas pressure
  • Accuracy: +/-2% FS
  • 0.01” WC resolution for static pressure
  • Includes tube and adaptor for gas measurement
  • Manual zero set for comparing 2 pressures
  • Auto off can be disabled for data logging with DL2 datalogger

View Operation Manual in PDF here.

AMN2

ATH4 - Dual Temperature Accessory

2 k-type thermocouple inputs. Display T1, T2 or T1 - T2.

  • Accuracy: +/- 0.5°C after calibration
  • Range: -45.5°C - 982°C (with optional thermocouple)
  • Displays °C directly at 0.1°C resolution with 0.1mVDC resoluion
  • Select °C or °F
  • Includes 2 “wrap tab” thermocouples insulated to 204.4°C plus velcro straps
  • Auto off can be disabled for data logging with DL2

View Operation Manual in PDF here.

ATH4_strap_therm

ATIR3 - Surface Temp Accessory

For quick surface temp measurement.

  • Measure temp without contact
  • 8:1 field of view
  • Laser sight included
  • Select °F or °C
  • Operating ambient temp: 0°C to 50°C at <75%RH
  • Range: 0°C to 400°C
  • Accuarcy: @ 22.8°F +/-5.5°C at <90%RH

View Operation Manual in PDF here.

ATIR3_2

AVG2 - Vacuum Accessory

Displays pressure in microns in steps of 1 micron. Has pump down indication showing progress from atmospheric pressure.

  • Range: 50 to 2000 microns of mercury
  • Resolution: 1 micron of mercury
  • Accuracy @23.9°C: +/-10%, 0 - 1000microns of mercury
  • Fitting: 1/4” flared brass male fitting
  • Auto off can be disabled for data logging
  • Straight access to sensor for easy cleaning
  • New “T” for inline vacuum testing
  • LEDs indicate INCreasing, DECreasing and STABLE vacuum

View Operation Manual in PDF here.

AVG2

AVH1 - Voltage Accessory

Records voltage using DL2 data logger or EHDL1 handle.

  • Accuracy DC +/-(0.5%rdg + 1 dgt)
  • AC +/-(1.0%rdg + 4dgts)
  • Max voltage: 600V AC or DC
  • Input impedance: 1MOhm
  • Standard test leads plug in top

View Operation Manual in PDF here.

AVH1

 

  - Home -    - Products -    - Downloads -    - Contact -  

Copyright © 2006 Fieldpiece Australia

Site By - Vicious Technology