PRODUCTS
Category: our product range >>Superheat & Subcooling

Sort by:
Displaying page 1 of 1 |

Standalone Superheat & Subcooling Meter - Code : SSX34

Use for real-time measurement of Superheat and Subcooling. Use the pressure port to measure and system pressure. Plug in your thermocouple to read temperature.

Features

  • Select R-134A, R-404A, R-410A or R-22
  • Magnetic Hanger on rubber protective boot
  • Resolution 0.1 kPa pressure high accuracy

TECHNICAL SPECIFICATIONS

  • Operating environment: 32F (0C) to 122F (50C) <75% RH
  • Storage environment: -4F (-20C) to 140F (60F) <80% RH with battery removed from meter.
  • Overrange: OL or -OL is displayed.
  • Auto-off power: 15 minutes
  • Temperature coefficient: 0.05 x (specified accuracy) per C
  • Accuracy: Stated accuracy at 23C 5 (73F 9F), <90%R.H.
  • Battery: Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22.
  • Low battery: A sideways battery is displayed on the LCD.

Temperature

  • Temperature Input: Standard K-type thermocouple connectors
  • Measurement range: -40 to 400F(-40 to 204C) (180F/82C max with supplied ATC1 pipe clamp thermocouple)
  • Resolution: 0.1
  • System accuracy after field calibration:
    1.0F @ -40 to 200F with field calibration
    0.5C @ -40 to 93C with field calibration
    2.0F @ 200 to 400F with field calibration
    1.0C @ 93 to 204C with field calibration

Pressure

  • Pressure Input: Standard 1/4 male flare fitting
  • Measurement range:
    29 HgV to 500PSIG (imperial)
    74 cmHgV to 0 to 4000KPa (metric)
    HgV indicates a vacuum measurement in either inches (imperial) or cm (metric) of mercury. A perfect vacuum would be 29.92HgV or 76.00cmHgV. Atmospheric pressure at sea level would be 0 HgV and 0 cmHgV.
  • System accuracy after field calibration:
    29 HgV to 0 HgV: 0.2 HgV
    74 cmHgV to 0 cmHgV: 0.4 cmHgV
    0 to 200 Psi: 1 Psi
    0 to 1378 KPa: 7 KPa
    200 to 500 Psi: 0.3%+1 Psi
    1378 to 3447KPa: 0.3%+7 KPa
  • Maximum overload pressure: 800PSIG
ATC1 - Pipe Clamp Thermocouple

What's Included

  • ATC1 - Pipe Clamp Thermocouple

/ ea

HVAC Guide System Analyser - Code : HG2

The HVAC Guide system analyser is the industry's first easy to use, hand held tool that leads field technicians step by step through critical HVAC tests.

A must for all Service Companies where Apprentices can use it to learn on the job. Review their stored readings for further training and analysis.

Click here to link to HG2 & HG3 Page

Check to see if your HVAC Guide is up to date.

Tests Include:

  1. Target Evaporator Exit Temp
  2. Superheat
  3. Subcooling
  4. Combustion Analysis
  5. Check Me. An overall system analysis

Features

  • Easy to use INPUT/OUTPUT FORMS to collect and analyse data.
  • Automatically enter data using Fieldpiece accessory heads.
  • Manually enter data using standalone equipment.
  • Sophisticated air conditioning analysis program based on data from 100,000 field tests (HG2 only).
  • Download test data to a PC.
  • Reload tests when returning to the same customer.
  • Test data can be delivered to the customer as a work order.

Specifications

  • Range - 500mVDC, 5VDC(auto)
  • Accuracy - 0.5% 2
  • Input Protection - MAX 30VDC/24VAC
  • Battery - 1.5v AA x 6 (installed)
  • Battery Life - 500hrs typical alkaline
  • Test Memory - upto 200 saved tests
  • Conversion - 1V = 1 count  1mV = 1 count (5VDC)
What Included With HVAC Guide

What's Included

  • ATH4 - Dual Temperature accessory head
  • ATWB1 - Wet Bulb thermocouple with alligator clip 
  • ATA1 - Bead type thermocouple with alligator clip
  • Software CD & Optical Cable
  • ANC5 - Padded Pouch Style

/ ea

Superheat & Subcooling Accessory Charging kit - Code : ASX14

Measure suction line pressure and temperature to calculate Superheat or Subcooling for R22 or410A. Attach to HS & LT Series meters, EHDL1 or Use with DL3 to log Pressure, Temperature, Subcooling or Superheat:

Features

  • Display pressure in PSI or kPa.
  • Display temperature in F or C.
  • Select R22 or R410A.
  • Auto-off can be disabled for data logging.
  • Includes "T" Piece Fitting
  • Accepts all K-type thermocouples.
  • ATC1 pipe clamp T/C included.
  • LED indicates when readings are stable.
  • Thermocouple calibration pot.
  • Push-button atmosphere pressure calibration.

TECHNICAL SPECIFICATIONS

  • Operating environment: 32F to 122F; 0C to 50C at <75%RH
    Allow ~5 min. for ASX14 to come to ambient temp.
  • Storage environment: -4F to 140F; -20C to 60C at <80%RH with battery removed.
  • Battery life: 25 hours typical. No measurable current draw when in "off" position.
  • Low battery indication: Red LED lights
  • Battery: 9V Auto off: Approx. 15 minutes
  • Overloads: The ASX14 outputs 3.4V when temperature or pressure is outside of their working range (overloaded). For ranges below 3400mVDC, the normal overload symbol will be displayed on the meter (OL). For ranges above 3400mVDC, reading displayed will be approximately 3.4VDC.
  • Stated Accuracy: at 73F 9F (23C 5C) <90% R.H.


Compatible Refrigerants

  • Built-in Pressure/Temperature Charts: R22, R410A.  PT charts for 12 refrigerants when used with HVAC Guide System Analyzer.

Temperature

  • Range (temperature): -40F to 400F; -40C to 204C
  • Resolutions: 0.1
  • Sensor type: k-type thermocouple
  • Pipe clamp thermocouple accuracy: 4F (2C) or 0.75%, whichever is greater, -30F to 200F (-34C to 93C)
  • System accuracy: 1F;0.06C @ 73F 5F after ice water calibration (see Field calibration).

Pressure and vacuum

  • Working range (pressure): 0 to 500 psi; 0 to 4000 kPa
  • Max displayed pressure: 800psi (5500 kPa)
  • Working range (vacuum): 29Hg vac. to 0; 74cmHg vac. to 0
    Vacuum will show up as negative value on meter.
  • Resolutions: 0.1psi or kPa, 0.1Hg or cmHg vac.
  • Accuracy: 0 to 200 psig, 1 psi, 0 to 1378 kPa 6.9 kPa; 200 to 500 psig, 0.3% 1 psi, 1378 to 3447 kPa 0.3% 6.9kPa
  • Sensor breakdown pressure: 800psi (5500 kPa)

Superheat

  • Range (temperature): 0F to 80F; 0C to 27C
  • Resolutions: 0.1
  • System Accuracy: 1F @ 73F 5F (0.06C @ 23C 3C) after calibration (see Field calibration).

Subcooling

  • Range (temperature): 0F to 80F; 0C to 27C
  • Resolutions: 0.1
  • System Accuracy: 1F @ 73F 5F (0.06C @ 23C 3C) after calibration
ATC1 - Pipe Clamp Thermocouple

What's Included

  • ATC1 - Pipe Clamp Thermocouple

/ ea

Superheat & Subcooling Accessory Charging kit - Code : ASX24

Measure suction line pressure and temperature to calculate Superheat or Subcooling for R-134a or R-404a. Attach to HS & LT Series meters, EHDL1 or Use with DL3 to log Pressure, Temperature, Subcooling or Superheat:

Features

  • Display pressure in PSI or kPa.
  • Display temperature in F or C.
  • Select R134A or R404A.
  • Auto-off can be disabled for data logging.
  • Includes "T" Piece Fitting
  • Accepts all K-type thermocouples.
  • ATC1 pipe clamp T/C included.
  • LED indicates when readings are stable.
  • Thermocouple calibration pot.
  • Push-button atmosphere pressure calibration.

TECHNICAL SPECIFICATIONS

  • Operating environment: 32F to 122F; 0C to 50C at <75%RH
    Allow ~5 min. for ASX24 to come to ambient temp.
  • Storage environment: -4F to 140F; -20C to 60C at <80%RH with battery removed.
  • Battery life: 25 hours typical. No measurable current draw when in "off" position.
  • Low battery indication: Red LED lights
  • Battery: 9V Auto off: Approx. 15 minutes
  • Overloads: The ASX24 outputs 3.4V when temperature or pressure is outside of their working range (overloaded). For ranges below 3400mVDC, the normal overload symbol will be displayed on the meter (OL). For ranges above 3400mVDC, reading displayed will be approximately 3.4VDC.
  • Stated Accuracy: at 73F 9F (23C 5C) <90% R.H.


Compatible Refrigerants

  • Built-in Pressure/Temperature Charts: R134A, R404A.  PT charts for 12 refrigerants when used with HVAC Guide System Analyzer.

Temperature

  • Range (temperature): -40F to 400F; -40C to 204C
  • Resolutions: 0.1
  • Sensor type: k-type thermocouple
  • Pipe clamp thermocouple accuracy: 4F (2C) or 0.75%, whichever is greater, -30F to 200F (-34C to 93C)
  • System accuracy: 1F;0.06C @ 73F 5F after ice water calibration (see Field calibration).

Pressure and vacuum

  • Working range (pressure): 0 to 500 psi; 0 to 4000 kPa
  • Max displayed pressure: 800psi (5500 kPa)
  • Working range (vacuum): 29Hg vac. to 0; 74cmHg vac. to 0
    Vacuum will show up as negative value on meter.
  • Resolutions: 0.1psi or kPa, 0.1Hg or cmHg vac.
  • Accuracy: 0 to 200 psig, 1 psi, 0 to 1378 kPa 6.9 kPa; 200 to 500 psig, 0.3% 1 psi, 1378 to 3447 kPa 0.3% 6.9kPa
  • Sensor breakdown pressure: 800psi (5500 kPa)

Superheat

  • Range (temperature): 0F to 80F; 0C to 27C
  • Resolutions: 0.1
  • System Accuracy: 1F @ 73F 5F (0.06C @ 23C 3C) after calibration (see Field calibration).

Subcooling

  • Range (temperature): 0F to 80F; 0C to 27C
  • Resolutions: 0.1
  • System Accuracy: 1F @ 73F 5F (0.06C @ 23C 3C) after calibration
ATC1 - Pipe Clamp Thermocouple

What's Included

  • ATC1 - Pipe Clamp Thermocouple

/ ea

Superheat Accessory Charging Kit - Code : ASH3

Measure suction line pressure and temperature to calculate superheat for R-22 or R-410A. Attach to HS & LT Series meters, EHDL1 or Use with DL3 to log pressure, Temperature or Superheat:

Features

  • Display pressure in PSI or kPa.
  • Display temperature in F or C.
  • Select R22 or R410A.
  • Auto-off can be disabled for data logging.
  • Includes "T" Piece Fitting
  • Accepts all K-type thermocouples.
  • ATC1 pipe clamp T/C included.
  • LED indicates when readings are stable.
  • Thermocouple calibration pot.
  • Push-button atmosphere pressure calibration.

TECHNICAL SPECIFICATIONS

  • Operating environment: 32F to 122F; 0C to 50C at <75%RH Allow ~5 min. for ASH3 to come to ambient temp.
  • Storage environment: -4F to 140F; 0C to 50C at <80%RH with battery removed from meter.
  • Battery life: 25 hours typical. No measurable current draw when in "off" position.
  • Low battery indication: Red LED lights
  • Battery: 9V. Auto off: Approx. 15 minutes
  • Overloads: The ASH3 outputs 3.4V when temperature or pressure is outside of their working range (overloaded). For ranges below 3400mVDC, the normal overload symbol will be displayed on the meter (OL or depending in the meter). For ranges above 3400mVDC, reading displayed will be approximately 3.4VDC.

Pressure and Vacuum

  • Working range (pressure): 0 to 500 psi; 0 to 4000 kPa
  • Maximum displayed pressure: 800psi
  • Working range (vacuum): 29Hg vac. to 0; 74cmHg vac. to 0
  • Vacuum will show up as negative value on meter.
  • Resolutions: 0.1psi, 0.1Hg vac.
  • Accuracy:
    @ 50F to 115F ambient, 1 psi, 6.9 kPa
    @ 32F to 122F ambient, 2 psi, 13.8 kPa
    Sensor breakdown pressure: 1300psi

Temperature

  • Range (temperature): -40F to 400F; -40C to 204C
  • Resolutions: 0.1
  • Sensor type: k-type thermocouple
  • Pipe clamp thermocouple accuracy: 4F or 0.75%, whichever is greater, -30F to 200F
  • System accuracy: 1F; 0.06C @ 73F 5F after ice water calibration (see Field calibration).

Superheat

  • Range (temperature): 0F to 80F; 0C to 27C
  • Resolutions: 0.1
  • System Accuracy: 1F; 0.06C @ 73F 5F after calibration (see Field calibration).
ATC1 - Pipe Clamp Thermocouple

What's Included

  • ATC1 - Pipe Clamp Thermocouple

/ ea

Diagnostic Psychrometer with Target Superheat - Code :SRH2

Use on Fixed Orifice Systems.  The quickest way to check your "Target" Superheat on a Fixed Orifice System by measuring the outdoor dry bulb temperature and the indoor wet bulb temperature.

Features

  • For temperature measurements select built-in thermistor or plug in thermocouple
  • Measures Wet bulb temp, dry bulb temp, dew point temp and %RH
  • Target Evap. Exit Temp and Target Superheat for "Fixed Orifice Systems"
  • Calculate target superheat amd target evaporator exit temperature
  • Rubber boot protection with magnetic hanger strap

TECHNICAL SPECIFICATIONS

  • Operating temperature: 0F - 122F at <75%RH
  • Storage Temperature: -4F to 140F (-20C to 60C) 0 to 80%RH with battery removed.
  • Low battery indication: The +- symbol is displayed when the battery drops below the operating level.
  • Battery Life: Approx. 150 hours (9V alkaline)
  • Auto Power Off: After 15 minutes of non-usage.

Temperature (K-Type Thermocouple):

  • Range: -58F to 1832F (-50C to 1000C)
  • Accuracy: 1F 50F to 113F (0.5C 10C to 45C), when calibrated to NTC at room temperature
    (0.1% rdg+2F) -58F to 1832F
    (0.1% rdg+1C) -50C to 1000C

Temperature (NTC):

  • Range: 32F to 140F (0C to 60C)
  • Accuracy:
    1F 50F to 113F (0.5C 10C to 45C)
    4F 32F to 50F and 113F to 140F
    2C 0C to 10C and 45C to 60C
  • Relative Humidity: 0% to 100% RH range
  • Accuracy: 2.5% at 77F (25C), 10% to 90%RH
    5% at 77F (25C) 0 to 10% RH & 90 to 100%RH
What's Included With SRH2

What's Included

  • ATA1 -Thermocouple with aligator clip
  • ATWB1 - Wet Bulb Thermocouple with aligator clip
  • Standard 9V battery
  • Operations manual

/ ea